Gas Zone 1 Luminaires

SOLUCIONES ATEX

We are specialists in ATEX and high technical specification environments

The ATEX atmosphere corresponding to Zone 1 applies to areas where flammable gases or vapours may be present, such as petrol stations, chemical plants, paint booths or solvent storage facilities, among others. In this case, an explosive atmosphere is likely to form under normal operating conditions.

At Airfal, we offer lighting solutions (luminaires and floodlights) specifically designed for this environment, ensuring the highest required level of safety.

Gas Zone 1 Luminaires

ATEX: Gas Zone 1

An explosive atmosphere is a mixture with air, under atmospheric conditions, of flammable substances in the form of gases, vapours, mist or dust in which, after ignition, combustion spreads to the entire unburned mixture.

Many substances can form an explosive atmosphere. Examples include gases (natural gas, butane, propane, acetylene, etc.), liquids (fuels, solvents, oils, paints, etc.) and solids (wood, coal, cereal grains, metal dust). Therefore, many facilities and activities must be assessed in accordance with applicable regulations.

airfal-5
ip-2

There are two types of ATEX atmospheres: explosive gas atmospheres and explosive dust atmospheres.

When classifying zones, the relevant international standards and the parameters of the substances capable of creating these atmospheres must be taken into account. This makes it possible to classify the location based on the characteristics of the substances present in the facility.

Frequently Asked Questions about Gas Zone 1 Luminaires

What defines Gas Zone 1?2026-10-09T15:53:57+02:00

Gas Zone 1 is an area where an explosive atmosphere is likely to form during normal operation of the equipment.

Which regulations must luminaires for Gas Zone 1 comply with?2026-10-09T15:49:13+02:00

Equipment Directive 2014/34/EU: Regulates equipment used in explosive atmospheres.

  • Flameproof enclosure “db” UNE-EN 60079-1: Provides protection against internal explosions.
  • Flameproof enclosure “db” UNE-EN 60079-1: Provides protection against internal explosions.
  • Increased safety “eb/ec” UNE-EN 60079-7: Enhances safety through equipment design and construction.
  • Restricted breathing “n” UNE-EN 60079-15: Limits the ingress of explosive gases into the equipment.
  • Protection by enclosure “tb/tc” EN 60079-31: Provides protection through an enclosure resistant to dust and other contaminants.
How are the right luminaires selected for Gas Zone 1?2026-10-05T16:07:35+02:00

To select the right luminaires for Gas Zone 1, an ATEX zoning study must be carried out by the plant management, engineering department or facility safety team.